Leave Your Message
Stainless Steel Single Plate Wafer Check Valve
Wafer Check Valve
Products Categories
Application

Stainless Steel Single Plate Wafer Check Valve

Single plate wafer swing check valve is one type of wafer type swing check valve, which is normally mounted between two flanged piping as non-return valve. Wafer type single disc swing check valve is action depending on the mediums flow pressure automatically when the mediums flow back, preventing the medium from flowing back. The single plate wafer swing check valve can be mounted onto both horizontal and vertical direction pipelines. KEFA can manufacture the single plate wafer swing check valve in accordance with ASME B16.34 and API594.

  • Series KF-SWCV
  • Type Metal Seal / Rubber Seal
  • Size DN50-250mm, NPS 2"-10"
  • Pressure Rating PN10 / PN16 / PN25, 150LB
  • Certificate ISO9001, CE
  • Sample Available
  • Service OEM & ODM

Features

Leakage Level

Bubbles-tight sealing with no leakage

Low Flow Resistance

Improve fluid efficiency and reduce energy consumption

Valve Design

Small size & light weight

Easy Install

Either vertically or horizontally installed

Compact Structure

Quick and automatic closure via torsion spring

Applicable Medium

Water, drink water, oil, gas, seawater, neutral liquid, etc

Certificates

ISO9001, CE, WRAS, ACS

Specifications

Stainless Steel CF8/CF8M/CF3M, etc

Design Standard

API 594

End Flange Standard

PN10/PN16/PN25, 150LB

Testing Standard

API 598

Temperature

-20℃~160℃ (depends on the sealing material)

Body Material

Disc Material

Stainless Steel

Seat Material

Stainless Steel, FKM/EPDM/NBR

Spring Material

SS316, Inconel X-750

Dimension

Size

L

Ф D

Ф D1

EN558-1 Series 16

API594 125LB

API594 150LB

PN10

PN16

API594 125/150LB

EN558-1 Series 16

API594 125/150LB

DN50

43

54

60

108

103

65.5

65

DN65

46

60

67

128

122

78.5

78

DN80

64

67

73

143

135

94.5

94

DN100

64

67

73

163

173

116.7

117

DN125

70

83

83

193

195

145.5

145

DN150

76

95

98

219

221

170.5

171

DN200

89

127

127

271

278

224

224

DN250

114

140

146

329

338

265.5

276

DN300

114

181

181

377

385

408

310.5

328

DN350

127

184

184

439

445

449

360

375

DN400

140

191

191

490

496

513

410

416

DN450

152

203

203

540

557

548

450

467

DN500

152

213

219

595

616

605

505

514

DN600

178

222

222

697

736

716

624

616

DN700

229

305

305

812

806

830

720

720

DN800

241

305

305

919

913

938

825

DN900

241

368

368

1019

1013

1046

925

Working Principle ​ ​ ​

The single plate wafer check valve operates automatically according to the pressure difference across the valve. 

 When the upstream pressure is higher than the downstream pressure, the disc opens against the spring force, allowing fluid to pass through the valve. 

When the flow decreases or reverses, the spring pushes the disc back toward the seat. The disc closes to prevent reverse flow and help protect pumps, compressors, and other pipeline equipment. 

 The spring-assisted design supports faster closing compared with an equivalent non-spring-loaded swing check valve. Actual closing performance depends on flow velocity, spring selection, installation conditions, and system characteristics.

SS316 Wafer check valve

Typical Applications

Water Treatment
Chemical Processing
HVAC 
Systems
Marine Applications
FAQ

Frequently Asked Questions​​​

Everything you need to know about double eccentric butterfly valves, including design features, materials, applications and performance.

What is the difference between a single plate and a double plate wafer check valve?

A single plate check valve uses one disc to control reverse flow, while a double plate check valve uses two spring-loaded plates. Double plate designs generally offer a more balanced opening arrangement and are often preferred for larger pipeline applications. Single plate designs have a relatively simple disc structure.

Can the single plate wafer check valve be installed vertically?

Yes, depending on the valve design and spring configuration. Vertical installation with upward flow is generally possible for suitable models. Installation with downward flow must be confirmed with the manufacturer.

Is the valve suitable for chemical media?

It can be used for compatible chemical media. The stainless steel grade, seat material, and spring material must be selected according to the chemical composition, concentration, and operating temperature.

How does a single plate wafer check valve work?

When the upstream pressure exceeds the downstream pressure and the spring resistance, the disc opens to allow fluid to pass. When the flow decreases or reverses, the spring assists the disc in returning to the closed position, helping prevent backflow.

Does this check valve require an external actuator?

No. The single plate wafer check valve operates automatically through differential pressure and spring force. It does not require an electric actuator, pneumatic actuator, or manual operator.

SS316 Wafer check valve

Request a Quote

您的浏览器版本不支持canvas
您的浏览器版本不支持canvas